Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
 Discover the EKL19-40 RCBO from ETEK China – a compact and reliable solution for residual current and overcurrent protection. Ideal for use in residential and commercial buildings, it offers enhanced electrical safety and easy installation.
- Standard: IEC61009-1
 - Type: AC, A
 - Rated current: 6~40A
 - Rated voltage: 230/240 V~
 - Number of poles: Two-pole
 - Rated residual current (IΔn): 10, 30, 100, 300 mA
 - Rated short-circuit breaking capacity: 6 kA
 - Trigger characteristics: B, C
 - Ambient temperature: -25 to +40 ºC
 - Connection: Top and bottom
 - Certificates: CE, CB
 
 Discover the EKL19-40 RCBO from ETEK China – a compact and reliable solution for residual current and overcurrent protection. Ideal for use in residential and commercial buildings, it offers enhanced electrical safety and easy installation.
- Standard: IEC61009-1
 - Type: AC, A
 - Rated current: 6~40A
 - Rated voltage: 230/240 V~
 - Number of poles: Two-pole
 - Rated residual current (IΔn): 10, 30, 100, 300 mA
 - Rated short-circuit breaking capacity: 6 kA
 - Trigger characteristics: B, C
 - Ambient temperature: -25 to +40 ºC
 - Connection: Top and bottom
 - Certificates: CE, CB
 
Schaltbild
  Installationsgröße
  
| Parameter | Value | 
|---|---|
| Standard | IEC/EN61009-1 | 
| Protection | Ground fault, Overcurrent and short circuit | 
| Type of trip |            Ground fault: Electronic Overload and short circuit: Thermo-magnetic  |        
| No. of poles | 1P+N, 1 Module, N line with disconnected | 
| Type | AC, A | 
| Rated current (In) | 6, 10, 16, 20, 25, 32, 40A | 
| Rated sensitivity currents (I△n) | 10, 30, 100, 300mA | 
| Residual current off-time under I△n | ≤0.1s | 
| Reted residual making and breaking capacity (I△m) | 500A (In≤50A) | 
| Rated voltage (Ue) | 240V~ | 
| Rated frequency | 50/60Hz | 
| Rated breaking capacity | 6kA | 
| Energy limiting class | 3 | 
| Rated impulse withstand voltage (1.2/50) Uimp | 4,000V | 
| Dielectric test voltage at ind. Freq. for 1min | 2kV | 
| Thermal release characteristic | (1.13-1.45) x In | 
| Magnetic release characteristic | B: (3-5)x In, C: (5-10)x In | 
| Electrical life | 4,000 Cycles | 
| Mechanical life | 10,000 Cycles | 
| Contact position indicator | Yes | 
| Protection degree | IP20 | 
| Ambient temperature | -25℃~+40℃, Max.95% humidity | 
| Terminal connection type | Cable/Pin-type busbar | 
| Max. terminal size for cable | 16mm² | 
| Max. tightening torque | 2.5N.m | 
| Installation | Mounting on 35mm DIN rail | 
| Connection | From top and bottom |